Final assembly kit

PP 60 K-SE

No longer available for delivery
Article number: 0095.0204
Manufacturer: MAICO
Complete fan unit for PushPull 60 K single-room air extraction unit with heat recovery, comprising fan,... more information
Application examples: Single-family house, Multiple family unit, Office, Doctor's practice, Commercial premises
Product data sheet
PP 60 K-SE IM0015369.PNG Complete fan unit for PushPull 60 K single-room air extraction unit with heat recovery, comprising fan, ceramic heat exchanger, internal cover and 2 x G3 filters, accessories required: PP 60 KA-SR or PP 60 KL-SR shell kit and RLS PP-K room air control, optional accessory: PPH-K humidity sensor

Characteristic curve

Dimensioned drawing

PP 60 K-SE - Dimensioned drawing [mm]

  1. Cable entry

Technical data

PP 60 K-SE - Technical data

Article PP 60 K-SE
Air flow volume 17 m³/h / 22 m³/h / 30 m³/h / 41 m³/h / 50 m³/h / with PP 60 KA-SR and SRW shell kit
Energy efficiency class A
Maximum power consumption 2 W / 2,4 W / 2,9 W / 3,7 W / 4,8 W
Degree of protection IP X0
Installation position horizontal
System type Decentralised
Housing material Plastic EPP
Heat exchanger material Ceramic
Colour Traffic white, similar to RAL 9016
Weight 3,1 kg
Weight including packaging 3,824 kg
Type of filter Outside and exhaust air filter
Filter class G3 (optional M6)
Width 327 mm
Height 310 mm
Depth 268 mm
Width with packaging 325 mm
Height with packaging 290 mm
Depth with packaging 285 mm
Degree of heat provision > 80 %
Required room air control RLS PP-K
Sound pressure level 18 dB(A) / 23 dB(A) / 27 dB(A) / 32 dB(A) / 35 dB(A) / Distance 1 m, free-field conditions
Rated max. element normal difference in noise level Dn,w 44 dB
Packing unit 1 piece
Range K
GTIN (EAN) 4012799952046
Article number 0095.0204

Accessories

PP 60 K-SE - Accessories

Specific accessories

Product type Name Art. No. Price*(EUR) Action
Air filter, replacement PPF E1 0093.0082 on request
  • On the notes
Air filter, replacement PPF E2 0093.0086 on request
  • On the notes
Room air control RLS PP-K 0157.0199 on request
  • On the notes
Room air control RLS PP-K1 0157.0193 on request
  • On the notes
Humidity sensor PPH-K 0157.0200 on request
  • On the notes
Air filter, replacement PPF G3 No longer available for delivery 0093.0169 on request
  • On the notes
Air filter, replacement PPF M6 No longer available for delivery 0093.0170 on request
  • On the notes
Shell kit PP 60 KA-SR No longer available for delivery 0095.0205 on request
  • On the notes
Shell kit PP 60 KA-SRW No longer available for delivery 0095.0215 on request
  • On the notes
Shell kit PP 60 KA-SRL No longer available for delivery 0095.0216 on request
  • On the notes
Shell kit PP 60 KL-SR No longer available for delivery 0095.0206 on request
  • On the notes

Product description

Productdescription

PP 60 K-SE

short description

Complete fan unit for PushPull 60 K single-room air extraction unit with heat recovery, comprising fan, ceramic heat exchanger, internal cover and 2 x G3 filters, accessories required: PP 60 KA-SR or PP 60 KL-SR shell kit and RLS PP-K room air control, optional accessory: PPH-K humidity sensor

Product description

Features

  • Complete fan unit for PushPull 60 K single-room ventilation unit with ceramic heat exchanger, internal cover and two integrated G3 filters such that the air is filtered in both directions (optional: M6 fine dust filter).
  • Slide-in module complete with sound deadening EPP.
  • Accessories needed:
    • PP 60 KA-SR, PP 60 KA-SRW or PP KA 60 KA-SRL shell kit for external wall mounting or PP 60 KL-SR for soffit duct mounting.
    • RLS PP-K room air control.
  • Up to a maximum of 6 units can be controlled at the same time through an RLS PP-K room air control.
  • The PushPull 60 units are always operated in pairs. 2 x PushPull 60 units and 1 control are the minimum requirements.

Heat exchanger

  • Ceramic heat exchanger with alveolar air flow ducts.
  • Heat exchanger can be pulled out with ease after removing the internal cover and filter.

Heat recovery fan

  • A direct current fan for supply or exhaust air.
  • 5 ventilation levels with heat recovery:
    • The ventilation levels vary depending on shell kit model.
  • Further ventilation levels without heat recovery:
    • Cross-ventilation: One unit is permanently in supply air mode and the corresponding unit in exhaust air mode (e.g for cooling during a night in summer).
    • Dehumidification: Is switched manually. Units with humidity sensor run in cross-ventilation mode until the humidity has fallen below a particular value.
    • Level 0, the zero air level: Closes the external shutters if there are bad odours coming in from the outside. The unit does not consume electricity in the process.

Mounting instructions

  • Assembly involves 2 steps:
    • Installation of the PP 60 KA-SR shell kit for external wall mounting or the PP 60 KL-SR shell kit for soffit duct mounting in a DN 220 core hole.
    • Integration of PP 60 K-SE final assembly set.
  • The shell kit's wall sleeve is protected from contamination by plaster protective covers.
  • The covers are easy to remove.
  • No need to lay ducts.
  • The system requires no adjustment.

Electrical connection

  • When delivered, the unit is assembled and ready for service.
  • The electrical supply is connected using a plug connection.
  • Connection to RLS PP-K room air control using pluggable control cables.

Condensation drain

  • The condensate is removed via an integrated condensation drop catcher in the external cover.

Table of contents

Wiring diagram

PP 60 K-SE - Wiring diagram

Connection for PushPull 60 K ventilation units to RLS PP-K room air control

P - PushPull Fan

F - Fan

Kl - Shutter

St - Connector

NT - Mains adapter

SV - Power Supply



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings