Centralised ventilation unit

WS 470 KBET

Article number: 0095.0235
Manufacturer: MAICO
Centralised, highly-efficient ventilation units with EC fans, constant volumetric flow regulation including... more information
Application examples: Low-energy house, Living room
Product data sheet
WS 470 KBET IM0015769.PNG Centralised, highly-efficient ventilation units with EC fans, constant volumetric flow regulation including preheating register, bypass and enthalpy heat exchanger, supply and exhaust air on left, air volume 80 - 470 m³/h, connection diameter 4 x DN 160, 4 SVR 160 plug connectors needed to connect folded spiral-seams ducts, including RLS 1 WR control panel, including integrated web server and MAICO APP for mobile unit control, web tool, DIBT approval, passive house certificate, KNX, Modbus, Loxone and EnOcean connection possible
WS 470 KBET IM0019630.PNG Centralised, highly-efficient ventilation units with EC fans, constant volumetric flow regulation including preheating register, bypass and enthalpy heat exchanger, supply and exhaust air on left, air volume 80 - 470 m³/h, connection diameter 4 x DN 160, 4 SVR 160 plug connectors needed to connect folded spiral-seams ducts, including RLS 1 WR control panel, including integrated web server and MAICO APP for mobile unit control, web tool, DIBT approval, passive house certificate, KNX, Modbus, Loxone and EnOcean connection possible
WS 470 KBET IM0020225.PNG Centralised, highly-efficient ventilation units with EC fans, constant volumetric flow regulation including preheating register, bypass and enthalpy heat exchanger, supply and exhaust air on left, air volume 80 - 470 m³/h, connection diameter 4 x DN 160, 4 SVR 160 plug connectors needed to connect folded spiral-seams ducts, including RLS 1 WR control panel, including integrated web server and MAICO APP for mobile unit control, web tool, DIBT approval, passive house certificate, KNX, Modbus, Loxone and EnOcean connection possible
WS 470 KBET IM0019952.PNG Centralised, highly-efficient ventilation units with EC fans, constant volumetric flow regulation including preheating register, bypass and enthalpy heat exchanger, supply and exhaust air on left, air volume 80 - 470 m³/h, connection diameter 4 x DN 160, 4 SVR 160 plug connectors needed to connect folded spiral-seams ducts, including RLS 1 WR control panel, including integrated web server and MAICO APP for mobile unit control, web tool, DIBT approval, passive house certificate, KNX, Modbus, Loxone and EnOcean connection possible
WS 470 KBET IM0016031.PNG Centralised, highly-efficient ventilation units with EC fans, constant volumetric flow regulation including preheating register, bypass and enthalpy heat exchanger, supply and exhaust air on left, air volume 80 - 470 m³/h, connection diameter 4 x DN 160, 4 SVR 160 plug connectors needed to connect folded spiral-seams ducts, including RLS 1 WR control panel, including integrated web server and MAICO APP for mobile unit control, web tool, DIBT approval, passive house certificate, KNX, Modbus, Loxone and EnOcean connection possible
WS 470 KBET IM0013942.PNG Centralised, highly-efficient ventilation units with EC fans, constant volumetric flow regulation including preheating register, bypass and enthalpy heat exchanger, supply and exhaust air on left, air volume 80 - 470 m³/h, connection diameter 4 x DN 160, 4 SVR 160 plug connectors needed to connect folded spiral-seams ducts, including RLS 1 WR control panel, including integrated web server and MAICO APP for mobile unit control, web tool, DIBT approval, passive house certificate, KNX, Modbus, Loxone and EnOcean connection possible
WS 470 KBET IM0007254.PNG Centralised, highly-efficient ventilation units with EC fans, constant volumetric flow regulation including preheating register, bypass and enthalpy heat exchanger, supply and exhaust air on left, air volume 80 - 470 m³/h, connection diameter 4 x DN 160, 4 SVR 160 plug connectors needed to connect folded spiral-seams ducts, including RLS 1 WR control panel, including integrated web server and MAICO APP for mobile unit control, web tool, DIBT approval, passive house certificate, KNX, Modbus, Loxone and EnOcean connection possible
WS 470 KBET IM0016004.PNG Centralised, highly-efficient ventilation units with EC fans, constant volumetric flow regulation including preheating register, bypass and enthalpy heat exchanger, supply and exhaust air on left, air volume 80 - 470 m³/h, connection diameter 4 x DN 160, 4 SVR 160 plug connectors needed to connect folded spiral-seams ducts, including RLS 1 WR control panel, including integrated web server and MAICO APP for mobile unit control, web tool, DIBT approval, passive house certificate, KNX, Modbus, Loxone and EnOcean connection possible

Characteristic curve

WS 470 KBET - Characteristic curve

The figures shown indicate the preset ventilation levels ("factory settings").

1 = 160 m³/h, reduced ventilation (RV)

2 = 240 m³/h, nominal ventilation (NV)

3 = 320 m³/h, intensive ventilation (IV)

I = Interval or "humidity protection operation" depending on RV

Individual settings available:

RV = 80 m³/h - 470 m³/h

NV = 80 m³/h - 470 m³/h

IV = 80 m³/h - 470 m³/h

Essential condition: RV < NV < IV !

Dimensioned drawing

WS 470 KBET - Dimensioned drawing [mm]

  1. DN 160 supply air
  2. DN 160 exhaust air
  3. DN 160 outside air
  4. DN 160 outgoing air
  5. Unit switches / electric connections
  6. Condensation drain
  7. for DN 160 plug connector

Technical data

WS 470 KBET - Technical data

Article WS 470 KBET
Air flow volume 80 m³/h - 470 m³/h
SEC average -36,3 kWh/(m²*a)
Energy efficiency class A
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz/60 Hz
Power consumption in accordance with DIN EN 13141-7 (A7) 85 W
Stand-by power consumption < 1 W
Imax 11,5 A
Degree of protection IP 40
DIBT approval yes
PHI certification yes
SPI value 0,28 Wh/m³
Installation site floor / wall
System type Centralised
Housing material Galvanised sheet steel, powder coated
Heat exchanger material Synthetic material
Inner coating material Plastic EPP
Colour Traffic white (RAL 9016)
Weight 70,84 kg
Weight including packaging 83 kg
Filter class ISO Coarse 85 % (G4) / ISO ePM1 80 % (F7)
Connection diameter 160 mm
Connection diameter of condensation drain 1 1/2" (screen valve)
Width 841 mm
Height 857 mm
Depth 598 mm
Width with packaging 900 mm
Height with packaging 1.120 mm
Depth with packaging 650 mm
Airstream temperature at IMax -20 °C up to 40 °C
Max. degree of heat provision in accordance with DIN EN 13141-7 (A7) 93 %
Heat exchanger construction type Enthalpy cross-counterflow
Humidity recovery with enthalpy heat exchanger in accordance with DIN EN 13141-7 (A2) 60 %
Power of preheating register 1,8 kW
Position – exhaust air left
Bypass yes
Frost protection integrated
Enthalpy heat exchanger yes
Antifreeze circuit yes
Summer circuit ECO exhaust air / ECO supply air
Filter monitoring with time control
Humidity control integrated
CO2 regulation (optional) SKD
Air quality control (optional) EAQ 10/3
KNX connection (optional) K-SM
MODBUS interface integrated
Control unit included in scope of delivery. RLS 1 WR, App
Control unit (optional) RLS T2 WS, RLS G1 WS
EnOcean wireless integration (optional) E-SM
Mobile control yes
Housing emission sound pressure level 42 dB(A) / Spacing 1m, sound absorption 10 m²
Packing unit 1 piece
Range K
GTIN (EAN) 4012799952350
Article number 0095.0235

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA2 (dB(A))

30

38

43

46

46

38

27

20

50

LWA5 (dB(A))

43

44

41

41

45

37

28

14

50

LWA6 (dB(A))

50

55

56

55

55

41

36

35

62

LWA2= housing sound power level in dB.

LWA5= free inlet sound power level in dB.

LWA6= free outlet sound power level in dB.

LWA5, LWA6 = sound power level emitted to the free surroundings. Measured at a subsequent operating point on the connections facing the room. LWA5 Exhaust air connections, LWA6 Supply air connections.

Operating point: Reference volumetric flow 340 m³/h and external pressure 50 Pa

Accessories

WS 470 KBET - Accessories

Specific accessories

General accessories

Product type Name Art. No. Price*(EUR) Action
MAICOFlex ventilation duct system, round MAICOFlex MF flexible, round ventilation duct system - - -
MAICOAir ventilation duct system, round Flexible, round MAICOAir MA ventilation duct system - - -
MAICOTherm ventilation duct system, thermally insulated MAICOTherm MT thermally insulated ventilation duct system - - -
MAICOFlex ventilation duct system, round MAICOFlex flexible, round ventilation duct system - - -
MAICO FFS ventilation duct system, flat MAICO FFS flexible flat ventilation duct system - - -
Outside air wall connection KW-AL 16E 0152.0077 on request
  • On the notes
Outside air wall connection KW-AL 16W 0152.0078 on request
  • On the notes
Outside air wall connection KW-AL 20E 0152.0081 on request
  • On the notes
Outside air wall connection KW-AL 20W 0152.0082 on request
  • On the notes
Outgoing air wall connection KW-FL 16E 0152.0079 on request
  • On the notes
Outgoing air wall connection KW-FL 16W 0152.0080 on request
  • On the notes
Outgoing air wall connection KW-FL 20E 0152.0083 on request
  • On the notes
Outgoing air wall connection KW-FL 20W 0152.0084 on request
  • On the notes
Combi-wall connections KWH 16 L 0152.0061 on request
  • On the notes
Combi-wall connections KWH 16 R 0152.0060 on request
  • On the notes
Combi-wall connections KWH 20 L 0152.0063 on request
  • On the notes
Combi-wall connections KWH 20 R 0152.0062 on request
  • On the notes
Roof outlet DF 160 S 0092.0375 on request
  • On the notes
Roofing tile DP 160 SB 0092.0380 on request
  • On the notes
Roofing tile DP 160 A 0092.0383 on request
  • On the notes
Mounting clamp BS 160 0092.0360 on request
  • On the notes
Rain protection grille RG 160 0151.0281 on request
  • On the notes
Door ventilation grille MLK 30 white 0151.0123 on request
  • On the notes
Door ventilation grille MLK 45 white 0151.0126 on request
  • On the notes
Exhaust and supply air valve AZV 100 0152.0087 on request
  • On the notes
Disk valve, synthetic material TK 10 0151.0192 on request
  • On the notes
Disk valve, synthetic material TK 12 0151.0198 on request
  • On the notes
Disk valve, metal TM 10 0151.0194 on request
  • On the notes
Disk valve, metal TM 12 0151.0196 on request
  • On the notes
Disk valve, stainless steel TM-V2A 10 0151.0374 on request
  • On the notes
Disk valve, stainless steel TM-V2A 12 0151.0375 on request
  • On the notes
Disk valve, metal TFA 10 0151.0369 on request
  • On the notes
Disk valve, metal TFA 12 0151.0370 on request
  • On the notes
Disk valve, metal TFZ 10 0151.0364 on request
  • On the notes
Disk valve, metal TFZ 12 0151.0365 on request
  • On the notes
Mounting frame for TFA/TFZ EBR-D 10 0092.0493 on request
  • On the notes
Mounting frame for TFA/TFZ EBR-D 12 0092.0494 on request
  • On the notes
Blower nozzle WD 10 W 0151.0290 on request
  • On the notes
Blower nozzle WD 10 D 0151.0291 on request
  • On the notes
Supply air valve ZWVQ 10 0152.0064 on request
  • On the notes
Supply air valve ZWVQ 12 0152.0065 on request
  • On the notes
Grease filter element for exhaust air FFE 10 0092.0506 on request
  • On the notes
Sound absorber box SB 12/16 0059.0995 on request
  • On the notes
Tubular sound absorber RSR 16/50 Discontinued product 0092.0324 on request
  • On the notes
Tubular sound absorber RSR 16-1 0092.0595 on request
  • On the notes
Tubular sound absorber RSR 16/50-1 0092.0603 on request
  • On the notes
Flat oval duct sound absorber RSOF 16/50 0092.0532 on request
  • On the notes
Flat oval duct sound absorber RSOF 16/100 0092.0535 on request
  • On the notes
Electrical air heater ERH 16-2 0082.0102 on request
  • On the notes
Water air heater WRH 16-2 0082.0118 on request
  • On the notes
Air filter TFE 16-4 0149.0077 on request
  • On the notes
Air filter TFE 16-7 0149.0052 on request
  • On the notes
Thermostat TH 10 0157.0764 on request
  • On the notes
Temperature control system DTL 16 P 0157.0825 on request
  • On the notes
Temperature control system DTL 24 P 0157.0586 on request
  • On the notes
Channel sensor FL 30 P 0157.0780 on request
  • On the notes
Room sensor FR 30 P 0157.0781 on request
  • On the notes
Air flow monitor LW 9 0157.0779 on request
  • On the notes
Humidity and temperature sensor FFT 30 K 0157.0121 on request
  • On the notes
CO2 sensor SKD 0157.0345 on request
  • On the notes
Air quality controller EAQ 10/3 Discontinued product 0157.0829 on request
  • On the notes
Thermally insulated long pipe elbow ABLS 160 No longer available for delivery 0058.0048 on request
  • On the notes
Tubular sound absorber RSR 16 No longer available for delivery 0092.0314 on request
  • On the notes
Radio switch XS 1 No longer available for delivery 0157.0344 on request
  • On the notes
Radio receiver XE 1 No longer available for delivery 0157.0343 on request
  • On the notes
Brine-air heat exchanger EW-K 225 No longer available for delivery 0192.0520 on request
  • On the notes
Stainless steel cowl LH-V2A 16 No longer available for delivery 0151.0380 on request
  • On the notes
Internal grille, adjustable AZE 100 No longer available for delivery 0059.0959 on request
  • On the notes
Internal grille, adjustable AZE 100 P No longer available for delivery 0059.0962 on request
  • On the notes
Air filter TFE 16-5 No longer available for delivery 0149.0061 on request
  • On the notes
Temperature control system ETL 16 P No longer available for delivery 0157.0824 on request
  • On the notes

Product description

Productdescription

WS 470 KBET

short description

Centralised, highly-efficient ventilation units with EC fans, constant volumetric flow regulation including preheating register, bypass and enthalpy heat exchanger, supply and exhaust air on left, air volume 80 - 470 m³/h, connection diameter 4 x DN 160, 4 SVR 160 plug connectors needed to connect folded spiral-seams ducts, including RLS 1 WR control panel, including integrated web server and MAICO APP for mobile unit control, web tool, DIBT approval, passive house certificate, KNX, Modbus, Loxone and EnOcean connection possible

Product description

Comfort bypass model

  • With preheating register, bypass and enthalpy heat exchanger.
  • Unit in left-hand version.
  • Modulating, automatic 100% bypass for passive summer night cooling with adjustable minimum supply air temperature limit.

Brief description

  • Central, compact, very quiet domestic ventilation unit with heat recovery.
  • For controlled ventilation and air extraction.
  • Highly efficient ventilation unit achieves energy efficiency class A without optional accessories.
  • Especially suitable for modern new buildings and redevelopments.
  • KfW and NRW subsidies are available.
  • Installed on wall or upright (optional).
  • ISO Coarse 85 % (G4) filter in the exhaust air and ISO ePM1 80 % (F7) pollen filter in the outside air. A filter cascade (ISO Coarse 85 % / ISO ePM1 80 %) in the outside air is possible to increase the filter service life.
  • All units are equipped with state-of-the-art cross-counterflow heat exchangers or enthalpy heat exchangers with hygiene certificates according to VDI 6022, sheet 1.
  • Complete separation of exhaust air/supply air ducts throughout the unit. This prevents unwanted recirculation of air. Viruses (e.g. Corona virus) and bacteria are therefore not transmitted.
  • RLS 1 WR room air control system included in the scope of delivery.
  • All domestic ventilation units can be controlled via the APP (air@home) and the browser-based web tool (www.air-home.de) using an integrated LAN interface.
  • USB connection as a standard feature for commissioning, control system update and service.
  • All units are equipped with highly energy-efficient fans with EC technology.
  • The integrated/automatic constant volumetric flow control ensures permanent compliance with the set volumetric flow under all operating conditions (e.g. filter contamination, air valve settings). This also results in easier commissioning/air volume measurement at the valves.
  • Combination sensor (humidity/temperature) integrated as a standard feature in the exhaust air enables demand-driven ventilation operation as well as an intelligent frost protection and dehumidification strategy (excess humidity protection).
  • All units are characterized by a frost protection strategy adapted to the real demand.
  • In addition, all units have a multifunction contact for the control of, e.g., a brine earth heat exchanger (unregulated pump), operation and fault display, preheating or supplementary heat register, external shutters or cooling.
  • Two input contacts (12 V and 230 V) are available for, e.g., safety shutdown.
  • Various inputs/outputs enable a control connection to other building service installations, e.g., the heat pump.
  • Integrated MODBUS interface (TCP/IP and RTU) enables integration in the building control system.
  • The optional K-SM plug-in module enables integration into KNX building control systems.
  • The optional E-SM plug-in module enables integration into EnOcean systems.
  • Optional additional circuit boards ZP 1 and ZP 2 for expansion functions such as “pressure constancy control” of the EC fans, zone shutter, brine earth heat exchanger (regulated pump), filter differential pressure measurement.
  • Maximum unit flexibility thanks to a wide range of equipment/connection options.
  • Modern unit module technology allows easy retrofitting (e.g. pre-heating, bypass) as well as high user-friendliness for service and maintenance.

Features

Housing

  • Powder-coated sheet steel housing.
  • Colour: traffic white, similar to RAL 9016.
  • Simple filter change is possible without tools.
  • Tight, thermal bridge-free inner housing made of temperature-resistant, sound-absorbing and heat-insulating EPP material (average wall thickness 47 mm).
  • EPP housing with very good hygienic / non-hygroscopic properties.
  • Material checked by the Institute for Air Hygiene in accordance with VDI 6022.
  • Condensate tank integrated in EPP housing.
  • Unit surface and unit’s inner housing are easy to clean.
  • Sound-absorbing inner cladding in supply air channel.
  • Condensate drain via screen valve 1 ½“.
  • Optional DN 40 unit siphon (see accessories).

Filter:

  • ISO Coarse 85 % (G4) filter in the exhaust air and ISO ePM1 80 % (F7) pollen filter in the outside air.
  • Optional filter cascade (ISO Coarse 85 % / ISO ePM1 80 %) in the outside air possible to increase the filter service life.
  • Filter exchange without tools.

Operation

  • Ready for service with on/off switch.
  • RLS 1 WR control panel included in the scope of delivery, 4 air levels, filter change indicator, fault display.
  • Other control panels can be connected in parallel.
  • Mobile operation via APP (air@home) or browser-based web tool (www.air-home.de) via smartphone, laptop or PC enables, e.g.,
    • live reporting, user management
    • Demand-driven automatic operation / time-controlled automatic operation
    • Manual operation / OFF
    • ECO mode supply air or ECO mode exhaust air
    • Filter queries, error messages
  • Optional RLS T2 WS touchscreen control panel for the setting of:
    • 2 automatic operating modes (Auto Sensor / Auto Time)
    • 4 manual operating modes (ECO exhaust air / ECO supply air / MANUAL / OFF)
    • Complete commissioning of the heat recovery units possible
  • Optional RLS G1 WS design control panel:
    • ON/OFF
    • 5 levels
    • Automatic operation
    • ECO supply air, ECO exhaust air
    • Filter change and fault display
  • USB connection for service/commissioning – free MAICO commissioning software.
  • Network integration via integrated LAN interface.
  • Smart-Home ready (e.g. Loxone via Modbus TCP/IP).
  • Modbus TCP/IP and RTU integrated as a standard feature.
  • Optional KNX plug-in module K-SM for integration into building control system, www.knx.org.
  • Optional EnOcean plug-in module E-SM for integrating the unit into the “EnOcean world”, www.enocean-alliance.org.

Control system

  • Standard demand-driven volumetric flow regulation (“decisive humidity value”).
  • Continuously variable demand-driven adaptation of air volumes.
  • Integrated excess humidity protection function.
  • 3 temperature sensors in outside, outgoing and supply air.
  • 1 combination sensor (temperature and humidity) in exhaust air socket.
  • Up to four external sensors of different types (CO2, VOC, humidity) can be connected.
  • Multifunction contact for the control of e.g. brine earth heat exchanger (unregulated pump), operation and fault display, preheating or supplementary heat register, external shutters or cooling.
  • Inputs for safety shutdown via 12V contact or 230V contact (e.g. smoke detector, fire alarm, differential pressureless fireplace).
  • Additional pushbutton input for triggering time-limited intensive ventilation (intermittent ventilation).
  • Expandable via optional additional circuit board ZP 1 for the control of:
    • 3-way shutter (e.g. earth-air heat exchanger)
    • a regulated pump (e.g. brine earth heat exchanger)
    • of an air shutter of a zone control
    • Switching contact use for external supplementary heat register
  • Expandable via optional circuit board ZP 2 for:
    • Pressure constancy of the EC fans
    • Differential pressure controlled filter monitoring
  • Various inputs and outputs enable a control connection of the ventilation unit with another service installation, such as a heat pump.

Approvals and certificates

  • DiBt approval.
  • PH certification: all WS 470 left-hand versions.
  • Test report in accordance with DIN EN 13141-7.
  • Certificate according to Swiss “energie-cluster.ch”.
  • Hygiene certificates for housing material (EPP) and heat exchanger.
  • Entry in TZWL Bulletin.

Heat exchanger/heat recovery

  • Highly efficient cross-counterflow heat exchanger made of plastic (PS).
  • Heat recovery up to 96 %.
  • Humidity recovery up to 60 % (for ET units).
  • Hygiene certificate (no bacteria, virus growth / virus transfer) according to VDI 6022, sheet 1.
  • Heat exchanger can be cleaned with water, antimicrobial.
  • Units with enthalpy heat exchangers do not require a condensation connection.

Bypass

  • Included in the “B” unit variants.
  • Modulating, automatic 100% bypass for passive summer night cooling with adjustable minimum supply air temperature limit.

Frost protection

  • Prevention of the heat exchanger freezing at low temperatures.
  • Highly energy-efficient frost protection function for “K” unit models via demand-controlled, power-modulated, electric PTC preheating register.
  • For “non-K” unit models via supply air fan switch-off.
  • Recommendation: For “non-K” unit models, combine the heat recovery with a brine heat exchanger.

Fans

  • Forward curved centrifugal fans in the supply air or outgoing air.
  • Energy-efficient EC direct current motors with integrated volumetric flow consistency control.
  • Possibility of pressure consistency control via the optional additional circuit board ZP 2.
  • 4 ventilation levels from 80 m³/h to 470 m³/h, can be adjusted continuously.

Installation information

  • Easy, very time-saving installation with the wall bracket included in the scope of delivery.
  • Housing cover is easy to remove using practical magnetic locks.
  • Provide sound absorbers on the supply air and exhaust air sides.
  • Comments: All unit variants (e.g. "K") can be converted into other unit variants (e.g. "KRET") later on using optional components.

Table of contents

Wiring diagram

WS 470 KBET - Wiring diagram

A - Ventilation unit WR 310/410, WS 320/470

A1 - Electronic slide-in module

A2 - Controlled domestic ventilation unit control

B - Simple control unit RLS 1 WR

B2-B5 - Parallel connection max. 5 RLS 1 WR

BT1 - RLS T1 WS touchscreen control unit

W1 - 230 V AC connecting cable

W2 - Screened control cable for simple control unit (provided by customer), e.g. LIYY 6 x 0.34 mm²

W2 - Screened control cable RLS T1 WS (provided by customer), e.g. LIYY 4 x 0.34 mm²

W5 - Connecting cable for PTC heat register

W6 Connecting cable (provided by customer) for multi-function contact (potential-free relay contact 230 VAC/5A or 30 VDC/5A). Multi-function contact for connecting one of the following components: Alarm display, filter change message, operating display, supplementary heating, pre-heating, shutter, brine EHE (uncontrolled pump), cooling.

W7 - Connecting cable for bypass motor

S1 - Unit switch

M1 - Exhaust air/outgoing air fan

M2 - Outside air/supply air fan

M3 - Bypass motor

T-LET - Temperature sensor for air inlet for outside air

T-FOL - Temperature sensor for outgoing air

T-ZUL - Temperature sensor for supply air

S-ABL - Combination sensor for exhaust air



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings